1db2a9eb67
test / integration-docker (pull_request) Successful in 17s
tracker-policy-pr / check-pr (pull_request) Successful in 16s
test / unit (pull_request) Successful in 39s
lint / lint (push) Successful in 56s
test / integration-firecracker (pull_request) Successful in 3m21s
test / coverage (pull_request) Successful in 19s
test / publish-infra (pull_request) Has been skipped
Review follow-up on #469: the data plane held the same control-plane secret that authorizes every route, so a compromised egress/git-gate could queue a supervise proposal AND approve it (or rewrite policy, read injected tokens) — the (source_ip, identity_token) checks attribute the *bottle*, not the caller. Replace the single shared bearer secret with role-scoped, HMAC-signed tokens (compact HS256 JWTs, stdlib-only — no new dependency): * new `control_auth` mints/verifies `{role}` tokens; roles are `gateway` (data plane) and `cli` (host operator/launcher). * the orchestrator holds only the signing *key* and verifies; `dispatch` gates each route by role — `gateway` reaches /resolve + /supervise/ {propose,poll}, everything else is `cli`-only (401 unauthenticated, 403 wrong role). * the gateway is handed a pre-minted `gateway` token it cannot rewrite into `cli`; the host CLI mints its own `cli` token from the host key. * `gateway_init` scopes the signing key to the orchestrator process and the gateway token to the data-plane daemons, so even in the combined infra container a compromised data-plane daemon never sees the key. Launchers (docker gateway + infra, macOS infra) inject the minted token(s); Firecracker stays open behind its nft boundary. Open mode (no key) still grants full `cli` access — the fail-visible fallback for tests. Co-Authored-By: Claude Opus 4.8 <noreply@anthropic.com>
414 lines
16 KiB
Python
414 lines
16 KiB
Python
"""Gateway data-plane supervisor (PRD 0070; PRD 0024 bundle shape).
|
|
|
|
PID 1 inside the `bot-bottle-gateway` data-plane image. Spawns
|
|
the configured daemons (egress, git-gate, supervise),
|
|
forwards SIGTERM/SIGINT to each child, and propagates per-daemon
|
|
stdout+stderr to the container log with a `[name] ` prefix.
|
|
|
|
Failure policy: when a child dies unexpectedly, the supervisor
|
|
restarts it automatically and logs the restart. The gateway stays
|
|
up; a temporary loss of one daemon (e.g. egress OOM-killed) is
|
|
recovered without manual container recreation. The supervisor
|
|
itself exits only when the operator sends SIGTERM/SIGINT.
|
|
|
|
Daemon subset is env-driven via `BOT_BOTTLE_GATEWAY_DAEMONS=egress`
|
|
for callers that don't use git-gate or supervise. Default: all
|
|
daemons.
|
|
|
|
Stdlib-only by design — adding supervisord/s6/runit for four
|
|
daemons is heavier than this script.
|
|
"""
|
|
|
|
from __future__ import annotations
|
|
|
|
import os
|
|
import signal
|
|
import subprocess
|
|
import sys
|
|
import threading
|
|
import time
|
|
from dataclasses import dataclass
|
|
from typing import IO, Sequence
|
|
|
|
|
|
# Below compose's default 10s `stop_grace_period`. After this many
|
|
# seconds past SIGTERM, escalate to SIGKILL on any still-running
|
|
# child.
|
|
_GRACE_SECONDS = 8.0
|
|
|
|
# Tight enough that exits and signals propagate without lag; loose
|
|
# enough that the main loop isn't a CPU hog.
|
|
_POLL_INTERVAL = 0.1
|
|
|
|
|
|
@dataclass(frozen=True)
|
|
class _DaemonSpec:
|
|
name: str
|
|
argv: Sequence[str]
|
|
|
|
|
|
# Env-var name prefixes that carry egress-only credentials.
|
|
# `egress_apply.py` assigns `EGRESS_TOKEN_<n>` slots that egress
|
|
# reads to inject `Authorization` headers on configured routes;
|
|
# no other daemon in the bundle should see these values.
|
|
_EGRESS_ONLY_ENV_PREFIXES: tuple[str, ...] = ("EGRESS_TOKEN_",)
|
|
_READY_GATED_DAEMONS: tuple[str, ...] = ("git-gate", "git-http")
|
|
|
|
# The control-plane signing key is the orchestrator's alone — verifying tokens.
|
|
# The data-plane daemons instead hold the pre-minted `gateway` JWT they present.
|
|
# Scoping each to its process (even in the combined infra container) keeps a
|
|
# compromised data-plane daemon from reading the key and minting a `cli` token
|
|
# (issue #469 review). Values match paths.CONTROL_PLANE_TOKEN_ENV /
|
|
# CONTROL_AUTH_JWT_ENV; hardcoded here so this supervisor stays import-light.
|
|
_SIGNING_KEY_ENV = "BOT_BOTTLE_CONTROL_PLANE_TOKEN"
|
|
_GATEWAY_JWT_ENV = "BOT_BOTTLE_CONTROL_AUTH_JWT"
|
|
|
|
# Daemons that must be requested explicitly via BOT_BOTTLE_GATEWAY_DAEMONS
|
|
# and are NOT started in the default (env-var-unset) case. The orchestrator
|
|
# only runs in the combined infra container, never in a standalone gateway.
|
|
_OPT_IN_DAEMONS: frozenset[str] = frozenset({"orchestrator"})
|
|
|
|
|
|
def _env_for_daemon(name: str, base_env: dict[str, str]) -> dict[str, str]:
|
|
"""Per-daemon env, scoped to what each process legitimately needs.
|
|
Returns a fresh dict — callers can mutate without affecting `base_env`.
|
|
|
|
* `EGRESS_TOKEN_*` upstream-auth slots go to egress only.
|
|
* the control-plane signing key goes to the orchestrator only.
|
|
* the pre-minted `gateway` JWT goes to the data-plane daemons only (the
|
|
orchestrator verifies tokens, it never presents one)."""
|
|
env = dict(base_env)
|
|
if name != "egress":
|
|
env = {
|
|
k: v for k, v in env.items()
|
|
if not any(k.startswith(p) for p in _EGRESS_ONLY_ENV_PREFIXES)
|
|
}
|
|
if name == "orchestrator":
|
|
env.pop(_GATEWAY_JWT_ENV, None)
|
|
else:
|
|
env.pop(_SIGNING_KEY_ENV, None)
|
|
return env
|
|
|
|
|
|
# The orchestrator is listed first so it starts before the gateway daemons,
|
|
# giving the control plane a head start to accept /resolve calls. The gateway
|
|
# daemons tolerate early /resolve failures and retry per-request.
|
|
_DAEMONS: tuple[_DaemonSpec, ...] = (
|
|
_DaemonSpec("orchestrator", (
|
|
"python3", "-m", "bot_bottle.orchestrator",
|
|
"--host", "0.0.0.0", "--port", "8099", "--broker", "stub",
|
|
)),
|
|
_DaemonSpec("egress", ("/bin/sh", "/app/egress-entrypoint.sh")),
|
|
_DaemonSpec("git-gate", ("/bin/sh", "/git-gate-entrypoint.sh")),
|
|
_DaemonSpec("git-http", ("python3", "-m", "bot_bottle.git_http_backend")),
|
|
_DaemonSpec("supervise", ("python3", "-m", "bot_bottle.supervise_server")),
|
|
)
|
|
|
|
|
|
def _argv_for_daemon(name: str, argv: Sequence[str], env: dict[str, str]) -> list[str]:
|
|
ready_file = env.get("BOT_BOTTLE_GIT_GATE_READY_FILE", "").strip()
|
|
if name not in _READY_GATED_DAEMONS or not ready_file:
|
|
return list(argv)
|
|
return [
|
|
"/bin/sh",
|
|
"-c",
|
|
"while [ ! -f \"$BOT_BOTTLE_GIT_GATE_READY_FILE\" ]; do "
|
|
"sleep 0.1; "
|
|
"done; "
|
|
"exec \"$@\"",
|
|
name,
|
|
*argv,
|
|
]
|
|
|
|
|
|
def _selected_daemons(
|
|
env: dict[str, str],
|
|
all_daemons: Sequence[_DaemonSpec] | None = None,
|
|
) -> tuple[_DaemonSpec, ...]:
|
|
"""Filter the daemon set by the BOT_BOTTLE_GATEWAY_DAEMONS env var.
|
|
|
|
When the var is unset/empty, return all non-opt-in daemons (the
|
|
standard gateway subset). Opt-in daemons (e.g. `orchestrator`) only
|
|
run when explicitly named — they never start in a plain gateway
|
|
container that doesn't set the env var. Unknown names are ignored.
|
|
|
|
`all_daemons` defaults to `_DAEMONS` resolved at call time (not at
|
|
definition time), so tests can pass a custom list."""
|
|
if all_daemons is None:
|
|
all_daemons = _DAEMONS
|
|
raw = env.get("BOT_BOTTLE_GATEWAY_DAEMONS", "").strip()
|
|
if not raw:
|
|
return tuple(d for d in all_daemons if d.name not in _OPT_IN_DAEMONS)
|
|
wanted = {n.strip() for n in raw.split(",") if n.strip()}
|
|
return tuple(d for d in all_daemons if d.name in wanted)
|
|
|
|
|
|
def _log(msg: str) -> None:
|
|
sys.stdout.write(f"gateway-init: {msg}\n")
|
|
sys.stdout.flush()
|
|
|
|
|
|
def _pump(name: str, stream: IO[bytes]) -> None:
|
|
"""Read lines from `stream`, prefix with `[name]`, write to
|
|
stdout. Runs in its own thread per child; daemon=True so a
|
|
blocked read doesn't keep the process alive after main exits."""
|
|
for raw in iter(stream.readline, b""):
|
|
line = raw.decode("utf-8", errors="replace").rstrip("\n")
|
|
sys.stdout.write(f"[{name}] {line}\n")
|
|
sys.stdout.flush()
|
|
|
|
|
|
def _spawn(spec: _DaemonSpec) -> subprocess.Popen[bytes]:
|
|
env = _env_for_daemon(spec.name, dict(os.environ))
|
|
proc = subprocess.Popen( # pylint: disable=consider-using-with
|
|
_argv_for_daemon(spec.name, spec.argv, env),
|
|
stdout=subprocess.PIPE,
|
|
stderr=subprocess.STDOUT,
|
|
bufsize=0,
|
|
env=env,
|
|
)
|
|
threading.Thread(
|
|
target=_pump, args=(spec.name, proc.stdout), daemon=True
|
|
).start()
|
|
return proc
|
|
|
|
|
|
class _Supervisor:
|
|
"""Holds the running children + shutdown state. Pulled out so
|
|
the test suite can drive it with fake commands."""
|
|
|
|
def __init__(self, specs: Sequence[_DaemonSpec]):
|
|
self.specs = tuple(specs)
|
|
self.procs: list[tuple[_DaemonSpec, subprocess.Popen[bytes]]] = []
|
|
self.shutdown_at: float | None = None
|
|
# Names of children that have been logged as having exited
|
|
# so we only log each death once across watch-loop ticks.
|
|
self._logged_dead: set[str] = set()
|
|
# Signal handlers add daemon names here and return quickly.
|
|
# The main watch loop drains the set, so repeated restart
|
|
# requests for one daemon coalesce into one restart.
|
|
self._restart_requested: set[str] = set()
|
|
|
|
def start_all(self) -> None:
|
|
for spec in self.specs:
|
|
_log(f"starting {spec.name}")
|
|
self.procs.append((spec, _spawn(spec)))
|
|
|
|
def request_shutdown(self, reason: str) -> None:
|
|
if self.shutdown_at is not None:
|
|
return
|
|
self.shutdown_at = time.monotonic()
|
|
self._restart_requested.clear()
|
|
_log(f"shutting down ({reason}); forwarding SIGTERM")
|
|
for _, p in self.procs:
|
|
if p.poll() is None:
|
|
try:
|
|
p.terminate()
|
|
except ProcessLookupError:
|
|
pass
|
|
|
|
def _sigkill_all(self) -> None:
|
|
for _, p in self.procs:
|
|
if p.poll() is None:
|
|
try:
|
|
p.kill()
|
|
except ProcessLookupError:
|
|
pass
|
|
|
|
def request_restart(self, daemon_name: str) -> bool:
|
|
"""Queue a daemon restart for the main loop to process.
|
|
|
|
Signal handlers use this non-blocking path instead of doing
|
|
subprocess lifecycle work directly. Requests coalesce by
|
|
daemon name: one pending restart is enough to make the daemon
|
|
reread the latest config from disk.
|
|
|
|
Returns True iff a daemon by that name is known to the
|
|
supervisor and shutdown has not started."""
|
|
if self.shutdown_at is not None:
|
|
_log(f"restart {daemon_name} skipped; supervisor is shutting down")
|
|
return False
|
|
if not any(spec.name == daemon_name for spec, _ in self.procs):
|
|
return False
|
|
self._restart_requested.add(daemon_name)
|
|
return True
|
|
|
|
def tick(self) -> bool:
|
|
"""One iteration of the watch loop. Returns True when every
|
|
child has exited and the supervisor can return.
|
|
|
|
A child dying unexpectedly is logged and restarted but does
|
|
NOT initiate shutdown — see the module docstring's
|
|
failure-policy section. Shutdown is signal-driven only."""
|
|
restarted_children = bool(self._restart_requested)
|
|
self._drain_restart_requests()
|
|
|
|
for spec, p in self.procs:
|
|
rc = p.poll()
|
|
if rc is None or spec.name in self._logged_dead:
|
|
continue
|
|
self._logged_dead.add(spec.name)
|
|
if self.shutdown_at is None:
|
|
_log(f"{spec.name} exited with code {rc}; scheduling restart")
|
|
self._restart_requested.add(spec.name)
|
|
else:
|
|
_log(f"{spec.name} exited with code {rc}")
|
|
|
|
# Restart deaths discovered above before checking whether all
|
|
# processes are done. Deferring this until the next tick would make a
|
|
# single-daemon supervisor return True and exit with the restart still
|
|
# queued.
|
|
restarted_children |= bool(self._restart_requested)
|
|
self._drain_restart_requests()
|
|
|
|
if self.shutdown_at is not None:
|
|
elapsed = time.monotonic() - self.shutdown_at
|
|
if elapsed > _GRACE_SECONDS:
|
|
still_running = [
|
|
spec.name for spec, p in self.procs if p.poll() is None
|
|
]
|
|
if still_running:
|
|
_log(
|
|
f"grace ({_GRACE_SECONDS:.0f}s) elapsed; SIGKILL on "
|
|
f"{', '.join(still_running)}"
|
|
)
|
|
self._sigkill_all()
|
|
|
|
done = (
|
|
not restarted_children
|
|
and all(p.poll() is not None for _, p in self.procs)
|
|
)
|
|
if done:
|
|
for _, p in self.procs:
|
|
if p.stdout is not None:
|
|
p.stdout.close()
|
|
return done
|
|
|
|
def exit_code(self) -> int:
|
|
"""Positive child failures win; otherwise report success.
|
|
|
|
Python represents signal-terminated children as negative
|
|
return codes. A signal-only graceful shutdown should not leak
|
|
that platform-specific detail into the container exit status,
|
|
but a positive crash before shutdown should remain visible."""
|
|
positives = [
|
|
p.returncode for _, p in self.procs
|
|
if p.returncode is not None and p.returncode > 0
|
|
]
|
|
return max(positives, default=0)
|
|
|
|
def _drain_restart_requests(self) -> None:
|
|
if self.shutdown_at is not None:
|
|
self._restart_requested.clear()
|
|
return
|
|
requested = tuple(sorted(self._restart_requested))
|
|
self._restart_requested.clear()
|
|
for daemon_name in requested:
|
|
if self.shutdown_at is not None:
|
|
self._restart_requested.clear()
|
|
return
|
|
self.restart_daemon(daemon_name)
|
|
|
|
def forward_signal(self, sig: int, daemon_name: str) -> bool:
|
|
"""Forward a signal to one named child. Used by the SIGHUP
|
|
path: egress_apply.py runs `docker kill --signal HUP
|
|
<bundle>`, the host kernel delivers SIGHUP to PID 1 (this
|
|
supervisor), and we relay it to mitmdump so it reloads
|
|
its addon's routes.yaml. Returns True iff a live child by
|
|
that name was signaled."""
|
|
for spec, p in self.procs:
|
|
if spec.name != daemon_name:
|
|
continue
|
|
if p.poll() is not None:
|
|
_log(
|
|
f"SIGHUP for {daemon_name} dropped; daemon "
|
|
f"already exited (rc={p.returncode})"
|
|
)
|
|
return False
|
|
try:
|
|
p.send_signal(sig)
|
|
except ProcessLookupError:
|
|
return False
|
|
_log(f"forwarded {signal.Signals(sig).name} to {daemon_name}")
|
|
return True
|
|
return False
|
|
|
|
def restart_daemon(self, daemon_name: str, *, grace: float = 5.0) -> bool:
|
|
"""Terminate one named child and spawn a fresh one, leaving
|
|
the other daemons running. A daemon that has no in-process
|
|
reload can be restarted this way after its config file changes.
|
|
|
|
Behavior: SIGTERM → wait up to `grace` seconds → SIGKILL if
|
|
still alive → spawn a replacement under the same DaemonSpec.
|
|
The `procs` slot is updated in place so subsequent
|
|
forward_signal / shutdown calls reach the new pid.
|
|
|
|
Returns True iff a daemon by that name was running and a
|
|
replacement spawned; False if no such daemon (not wired
|
|
for this bottle)."""
|
|
if self.shutdown_at is not None:
|
|
_log(f"restart {daemon_name} skipped; supervisor is shutting down")
|
|
return False
|
|
for idx, (spec, p) in enumerate(self.procs):
|
|
if spec.name != daemon_name:
|
|
continue
|
|
_log(f"restarting {daemon_name}")
|
|
if p.poll() is None:
|
|
try:
|
|
p.terminate()
|
|
except ProcessLookupError:
|
|
pass
|
|
try:
|
|
p.wait(timeout=grace)
|
|
except subprocess.TimeoutExpired:
|
|
_log(
|
|
f"{daemon_name} did not exit within {grace:.0f}s "
|
|
f"of SIGTERM; SIGKILL"
|
|
)
|
|
try:
|
|
p.kill()
|
|
except ProcessLookupError:
|
|
pass
|
|
p.wait()
|
|
if p.stdout is not None:
|
|
p.stdout.close()
|
|
self._logged_dead.discard(daemon_name)
|
|
new_proc = _spawn(spec)
|
|
self.procs[idx] = (spec, new_proc)
|
|
_log(f"{daemon_name} restarted (pid {new_proc.pid})")
|
|
return True
|
|
return False
|
|
|
|
|
|
def main(argv: Sequence[str] | None = None) -> int:
|
|
del argv # no flags yet; env-driven only
|
|
specs = _selected_daemons(dict(os.environ))
|
|
if not specs:
|
|
_log("no daemons selected; nothing to do")
|
|
return 0
|
|
|
|
sup = _Supervisor(specs)
|
|
sup.start_all()
|
|
|
|
signal.signal(signal.SIGTERM, lambda *_: sup.request_shutdown("SIGTERM")) # type: ignore
|
|
signal.signal(signal.SIGINT, lambda *_: sup.request_shutdown("SIGINT")) # type: ignore
|
|
# SIGHUP reload path: egress_apply.py runs `docker kill
|
|
# --signal HUP <bundle>` after writing routes.yaml. The kernel
|
|
# delivers SIGHUP to PID 1 (this supervisor); forward it to
|
|
# mitmdump so it reloads its addon.
|
|
signal.signal(
|
|
signal.SIGHUP,
|
|
lambda *_: sup.forward_signal(signal.SIGHUP, "egress"), # type: ignore[misc]
|
|
)
|
|
|
|
while not sup.tick():
|
|
time.sleep(_POLL_INTERVAL)
|
|
|
|
rc = sup.exit_code()
|
|
_log(f"exit {rc}")
|
|
return rc
|
|
|
|
|
|
if __name__ == "__main__":
|
|